Neodymium magnets in an electric motor: grades, temperature, and demagnetization
Neodymium magnets are the source of power for an electric scooter or motorcycle motor. They are extraordinarily powerful for their size, but they have a weak point: heat. An overheated magnet loses some of its magnetization, sometimes forever, and the motor becomes permanently weaker. Knowing how to read a magnet grade and understanding what puts it at risk helps in choosing a motor and tuning it without damaging it.
The essentials
- A magnet grade like N42SH is read in two parts: the number indicates the strength, the letters indicate the temperature resistance.
- When moderately heated, a magnet weakens and then regains its strength upon cooling: this is reversible.
- Beyond its limit, it loses part of its magnetization for good: this is demagnetization.
- The danger is greatest when heat is combined with a strong current opposing the magnets, such as in aggressive field weakening.
- A temperature sensor in the motor, connected to the controller, is the best protection.
What a neodymium magnet is
The so-called "neodymium" magnet is an alloy of neodymium, iron, and boron, sintered and then magnetized. It is the most powerful family of permanent magnets that can be mass-produced. It is what allows electric scooter hub motors to produce a lot of torque in a small volume, without a gearbox.
The alloy rusts easily: magnets are therefore always protected by a coating, often nickel or resin. A magnet with a cracked or chipped coating can oxidize and disintegrate over time, which is sometimes visible when opening a motor that has been exposed to water.
Reading a grade: the number and the letters
Neodymium magnets are designated by a code such as N35, N42H, N38SH, or N40UH.
- The number indicates the magnetic energy the magnet can provide. The higher it is, the stronger the magnet is at room temperature.
- The letters that follow indicate its resistance to demagnetization when heated. Without a letter, the magnet is a standard grade; with the letters M, H, SH, UH, EH, or AH, it can withstand increasingly higher temperatures.
The two qualities compete: the strongest grades generally do not exist in the versions most resistant to heat, because a magnet that keeps its strength when hot is better than a record-breaking magnet that collapses on a hill.
| Letters | Indicative maximum operating temperature |
|---|---|
| None (N) | Approx. 80 °C |
| M | Approx. 100 °C |
| H | Approx. 120 °C |
| SH | Approx. 150 °C |
| UH | Approx. 180 °C |
| EH | Approx. 200 °C |
| AH | Approx. 220 to 230 °C depending on sources |
These values are those commonly given by magnet manufacturers for a favorable magnet shape. They are not a guarantee: the actual limit depends on the shape of the magnet and the magnetic circuit in which it works. Specialists speak of the permeance coefficient: a thin magnet with a large air gap in front of it demagnetizes more easily than a thick magnet in a well-closed circuit. In a motor, this limit therefore also depends on the design, not just the grade.
Reversible and irreversible loss
When a neodymium magnet heats up, its strength drops slightly, and the more so the hotter it gets. The motor then produces less torque for each ampere and requires more current for the same effort. As long as you stay below the grade's limit, this drop is reversible: upon cooling, the magnet regains its strength.
Beyond that, some of the magnet's small magnetic domains flip and do not return. The loss becomes irreversible: even when cold, the magnet remains weaker. The motor does not repair itself by cooling down; you have to replace the magnets or the entire rotor.
Typical symptoms of a demagnetized motor:
- less torque at startup and on hills, for the same setting;
- a slightly higher top speed, because the motor produces less voltage while spinning;
- a motor that heats up faster than before, since it requires more current;
- on an adjustable controller, a measured magnet flux lower than at the motor's first detection.
The real danger: heat plus opposing current
Temperature alone is not the only enemy. The current flowing through the windings also creates a magnetic field. In normal operation, it is oriented so as not to fight the magnets. But there are situations where part of the current directly opposes their field:
- field weakening, which voluntarily weakens the magnets' field to exceed the speed allowed by the voltage (see our guide on field weakening);
- a fault or short circuit in the controller or phases, which can send a very high current in the wrong direction;
- poor positioning of the position sensors, which causes the current to push incorrectly.
The hotter the magnet, the less opposing field is needed to demagnetize it. It is the combination of a motor that is already very hot and aggressive field weakening, typically at the end of a long straight line on a track, that causes the most damage.
The shape of the rotor also plays a role. In an interior permanent magnet motor, known as IPM, the magnets are housed in the rotor iron, which partially protects them from the opposing field. Our guide on IPM and SPM motors details this difference. Our RM30 motor for Sur-Ron Light Bee uses IPM technology, and its datasheet claims heat resistance up to 180°.
Protecting your motor's magnets
The best practices are simple, provided you apply them before the problem occurs:
- Connect the motor's temperature sensor to the controller and set a cautious power reduction threshold, then a cutoff threshold.
- Do not overuse field weakening, especially when hot and during long high-speed runs.
- Improve cooling for intensive use: our motor ventilation forces air through MHS, MHT, XHS, and XHT motors. A ventilated motor is no longer sealed: reserve for dry conditions and track use.
- Re-run motor detection from time to time on an adjustable controller, and compare the measured flux to the original value.
Where heat comes from, and how a hub motor dissipates it, is explained in our guide on electric motor heating.
Workshop tip
The temperature read by the sensor is that of the windings, not the magnets, which are on the rotating part. Magnets heat up more slowly but also cool down more slowly: after a track session, let the motor cool down before heading out for a series of high-speed runs, even if the sensor already shows a reasonable value.
Frequently asked questions
Can a demagnetized magnet be re-magnetized?
In a factory, with high-power equipment, a magnet can be re-magnetized. Once mounted in a hub motor, this is not realistic in the workshop: you replace the rotor or the magnets.
How do I know the grade of my motor's magnets?
It is rarely indicated on the motor. Only the manufacturer can provide it. Failing that, set cautious temperature thresholds in the controller and monitor the motor's behavior during the first rides.
Does cold damage neodymium magnets?
No, in winter temperatures, a neodymium magnet is even slightly stronger when cold. It is the battery that suffers from the cold, not the magnets.
Can an impact demagnetize a motor magnet?
An impact does not demagnetize a neodymium magnet, but it can crack or chip it, as the material is brittle. A fragment that breaks off inside the motor can rub and block the rotor: a rubbing noise after a fall warrants opening it up.
Why does my motor have a higher top speed after overheating?
Because weakened magnets produce less voltage while spinning: the motor reaches the battery limit later. This is a sign of demagnetization, accompanied by a loss of torque. It is not a gain.