Motor not spinning under VESC: Troubleshooting steps, from the simplest to the rarest issues
The VESC controller powers on, the VESC Tool connects, but the motor doesn't move when you accelerate. Don't worry: in most cases, it's not the motor or the controller that's broken, but rather a setting, an active protection feature, or a wiring issue. The best approach is to isolate the problem: Does the controller report an error? Does the motor turn when you command it directly from the VESC Tool? Does the throttle signal reach the controller? Here's the troubleshooting process we follow in the workshop.
The essentials
- Throughout the diagnostic process, ensure the rear wheel is raised and the transmission is in free wheel mode.
- First question: Is there a registered fault? The VESC Tool terminal indicates whether there is.
- Second question: Does the motor turn when using the manual control in the VESC Tool? If so, the problem lies with the throttle and the input application.
- Ensure that each setting you have modified has been correctly saved to the controller.
- An improperly configured limit (cut-off voltage, temperature, speed) can reduce the current to zero without displaying any visible error.
1. Read error codes
Connect to the VESC Tool terminal and type faults (or use the Print Faults command). The controller will list the most recent faults recorded, along with the measured values at that time. An overcurrent, voltage, temperature, or gate driver fault often provides a clear explanation. Our guide on VESC faults describes each one in detail.
Also, pay attention to any ongoing errors displayed in the real-time data. If an error reappears as soon as you try something, that's the one you need to address before anything else.
2. Order the motor directly
The computer version of VESC Tool has a manual control panel: you can request a small percentage of maximum power (Duty cycle) or a low current (Current), and then stop the motor. With the wheel raised, request a small value.
- The motor is running: This indicates that the motor, the controller, and the sensor are likely functioning correctly. The problem is probably with the throttle or the input signal: proceed to step 4.
- The motor is not turning, or is vibrating: The problem is likely related to the motor itself, its wiring, or its configuration. Proceed to step 3.
3. Motor side: configuration and wiring
- Has the detection been performed and saved? After the detection process, the values must be applied and then saved to the controller. A configuration read from a file without being saved will not have any effect. Please refer to our guide on FOC motor detection.
- **The correct motor type:** The **Motor Type** setting (on the **General** page) must be set to **FOC** for FOC detection to work.
- `Sensors : If the Sensor Mode is set to Hall Sensors but the sensor connector is disconnected or damaged, the motor may stutter or fail to start. Try switching to Sensorless mode to diagnose the issue, and then re-calibrate the sensors.`
- Troubleshooting: A disconnected phase, a melted connector, or a broken solder joint can prevent the motor from spinning properly. Inspect the connectors, and with the motor disconnected, check the windings: see our guide on how to test a motor with a multimeter.
- Mechanics: A brake that's sticking, a seized bearing, or a wheel that's locked up can be identified by turning the wheel by hand, with the controller turned off.
4. Input side: throttle and brake
- APP to Use (App Settings, General) must correspond to the input being used: ADC for an analog trigger, PPM for a receiver.
- The **Control Type** should not remain set to **Off**, which is the setting used during calibration.
- Throttle Voltage: In the Mapping tab of the ADC page, with the real-time data from the application enabled, the voltage should change when you press the throttle. If it doesn't change, the problem is either the throttle itself or its cable.
- Absolute Thresholds: If the voltage goes outside the range defined by ADC1 Abs Min Voltage to ADC1 Abs Max Voltage, the motor will be stopped.
- Safe Start: If the throttle was not at rest when the system was powered on, the motor will remain locked until the throttle is released for a sufficient amount of time.
- Kill Switch Mode: A kill switch configured on an active input will disable everything.
The complete step-by-step guide for configuring the ADC input is in our documentation.
5. The limits that bring the current back to zero
Some safety mechanisms can reduce the current to zero without necessarily displaying an error. This is common after loading a configuration intended for a different machine
| Adjustment | What's causing the problem? |
|---|---|
| Battery Voltage Cutoff - Start / End | These settings, which are configured above the actual battery voltage, bring the battery current back down to zero |
| MOSFET Temperature Cutoff, Motor Temperature Cutoff | A motor sensor that is incorrectly configured and reports a very high temperature will prevent the motor from operating |
| Maximum ERPM | A zero or very low value will prevent any acceleration |
| Motor Current Max, Battery Current Max | A zero or very low value will not produce any torque |
| Motor Current Max Scale | A zero-point scale cancels out the maximum current |
Compare with real-time data: battery voltage, displayed temperatures. Any absurd motor temperature or a cut-off voltage higher than the battery voltage will be immediately apparent.
6. Dual Controller System
If only one motor is not running on a dual-motor setup, please check that the "Multiple VESCs Over CAN" option is enabled on the main controller, that the CAN bus is properly connected, that both controllers have different identifiers (VESC ID), and the same firmware version. Refer to our guide on dual-motor VESC setups using CAN.
7. If nothing else works
If the controller no longer connects, reports a persistent grid driver error, smells burnt, or shows signs of water damage, it's time to have it inspected rather than continuing to try and use it. And if the scooter doesn't turn on at all, the problem is upstream: see our guide scooter that won't start.
Workshop tip
After each modification, write down the configuration, turn off, restart, and then test. Many "motor not turning" issues stem from settings that were changed on the screen but never saved, or from a "Safe Start" protection being triggered by the throttle being touched when the device is turned on. If you get stuck, our workshop offers diagnostics by the hour (https://rage-mechanics.com/en/our-products/1529-labor-30-minutes.html), and you can describe the problem to us before coming in.
Frequently Asked Questions
The motor spins in the VESC Tool, but not when using the throttle. Why is this happening?
The issue lies within the input settings: specifically, the "APP to Use," "Control Type," voltage calibration, absolute thresholds, or "Safe Start" settings. The motor and controller appear to be functioning correctly.
The motor is vibrating or making a growling noise without turning. What should I do?
It's often due to a poorly connected phase, disconnected Hall sensors, or a false detection. Try running in "Sensorless" mode to isolate the sensors, and check the phase connectors.
The motor was working, but it stopped running after a setting change. What should I do?
Go back to the saved configuration from before the change. If it works, compare the settings one by one. That's why we save a backup before making any modifications.
The motor only runs when the VESC Tool is connected. Why is this?
During the connection process, the VESC Tool sends keep-alive messages to prevent timeouts. Once disconnected, if the input receives no valid data, the motor will stop. Please check the input application and its wiring.
Is the controller definitely broken?
Rarely. It's usually only suspected after other potential issues, such as defects, settings, sensors, and wiring, have been ruled out.