Efficiency of an electric motor: Where do the losses go, and how can they be reduced?
Not all the energy that the battery sends to the motor is used to propel the vehicle forward. A portion is converted into heat within the copper windings, the iron core, the bearings, and the controller. Efficiency measures the percentage that actually becomes movement. An electric motor with magnets is generally very efficient, but its efficiency varies greatly depending on how it is used. Understanding where the energy losses occur explains both the range and the heat generation.
The essentials
- Efficiency is calculated as the mechanical power output divided by the electrical power input.
- Copper losses are dominant at high torque, iron losses are significant at high speeds, and friction is present everywhere to some extent.
- The controller itself has its own energy losses, which are in addition to those of the motor.
- A motor has an optimal operating zone where it is most efficient; outside of this zone, it consumes more power and generates more heat.
- Any energy loss is converted into heat. Higher efficiency means greater range and a cooler motor.
What the efficiency measurement indicates
The efficiency is calculated simply as follows:
Efficiency = Mechanical power at the axle ÷ Electrical power received
Electrical power is the product of voltage and current. Mechanical power is the product of torque and rotational speed. If a motor receives 1000W and delivers 900W to the wheel, its efficiency at that operating point is 90%, and 100W is lost as heat. This figure is an example of a calculation and is not a value specific to our motors.
Important point: efficiency is not a single value for a motor. It changes with each torque and speed level. A single figure listed in a datasheet only corresponds to a specific operating point, often the most favorable one.
Copper losses
The current flows through the windings, which have a small amount of resistance. The heat generated increases with the square of the current. Since torque is proportional to the current, these losses become significant when a large amount of torque is required: during starts, when climbing hills, during acceleration, or when carrying a heavy rider.
At very low speeds and high torque, the mechanical power is low (as it is the product of torque and speed), while copper losses are at their maximum. Consequently, the efficiency is poor. This is typical of climbing a steep hill slowly, or starting from a standstill with a heavily loaded motor.
The mechanisms behind copper losses and iron losses are detailed in our guide why an electric motor heats up; here, we will focus on the energy they consume.
Iron losses
The magnetic field reverses in the stator laminations during each electrical cycle. This creates hysteresis losses and eddy current losses, which increase with frequency, and therefore with the motor's speed and the number of its poles. These losses exist even when the motor is unloaded: a hub motor spinning freely consumes some power, largely due to these losses.
Defluxing, which allows you to exceed the speed limit imposed by the voltage, adds current without producing useful torque; it significantly degrades efficiency at high speeds.
Mechanical losses
- Bearings: A slight amount of friction is present, which increases if the bearings are dry, damaged, or overtightened.
- Air circulation inside the motor, and outside for a rotor that spins quickly.
- Seals and, in a motor filled with ferrofluid, the viscous braking effect of the liquid within the air gap.
- The drivetrain, for a motor that is not integrated into the wheel: chain, belt, or gearbox all add to the energy losses.
These losses are lower than the electrical losses in a motor that is in good condition, but a worn bearing can significantly increase them.
Controller losses
The controller is not just a simple component. Its transistors lose energy through conduction, proportionally to the square of the current, and with each switching cycle, proportionally to the switching frequency. Its capacitors and traces also generate heat. Therefore, the actual efficiency seen from the battery is the product of the controller's efficiency and the motor's efficiency, not including the cables and connectors, which also have their own resistance.
A controller setting can either improve or degrade this overall performance: a properly tuned vector control system delivers power at the correct angle and avoids unnecessary current draw; conversely, a faulty motor detection system will have the opposite effect.
The efficiency map: this is where the motor operates most efficiently
On a test bench, we measure the efficiency for numerous combinations of torque and speed, and then we create a map with curves of equal efficiency, similar to the contour lines on a hiking map. Our guide on the motor test bench explains how these measurements are taken.
| Situation: | Dominant losses | Efficiency |
|---|---|---|
| Starting or riding slowly uphill with high torque | Copper | Bad |
| Average speed, moderate torque | Balance of copper and iron | Generally speaking, the best option |
| Very high speed, overheating | Flux and soldering current | Decreasing |
| Very low charge, wheel almost free-spinning | Iron and friction, resulting in minimal usable power | Low power, but with significant potential |
For a scooter hub motor, the most efficient operating range is generally at a sustained speed with moderate torque, meaning cruising on a flat surface. This is where the motor consumes the least amount of energy per kilometer traveled, at the same speed. Repeated starts, inclines, and bursts of speed in flux mode are the situations that consume the most energy.
Performance, range, and heat management
Every watt lost is a watt taken from the battery and converted into heat. Improving efficiency therefore provides two benefits: increased range and a cooler motor, which maintains its performance better over time. Our guide on the actual range of an electric scooter details other factors, starting with speed and aerodynamics.
The choice of motor is also important: a larger motor produces the same torque with less current per unit of copper, and operates more often within its optimal range. This is one of the reasons to upgrade to a larger motor on a heavily used machine; see our electric scooter motors. For a machine designed from scratch, our engineering department selects the motor and gearing to ensure that the primary use case falls within the optimal efficiency range.
Workshop tip
A machine that gets hotter than before for the same usage has lost efficiency somewhere: a worn bearing, a connector that overheats, weakened magnets after overheating, or a modified controller setting. Investigate the cause before adding cooling.
Frequently Asked Questions
Is an electric motor more efficient than a combustion engine?
Yes, definitely: an electric motor with magnets converts the majority of the energy it receives into motion, while a combustion engine loses most of its energy as heat. However, a fair comparison requires considering the production of the electricity or fuel used.
Why does my electric scooter consume so much more power in the city?
Repeated starts cause the motor to operate at high torque and low speed, where copper losses are significant and useful power output is low. During normal cruising, the motor operates in a much more efficient range.
Does regenerative braking compensate for energy losses?
It recovers some of this energy during braking, but the motor and controller also experience losses in this process. While there is a gain in range, it remains limited; the primary benefit is often to reduce the strain on the brakes.
Is it possible to measure the efficiency of your motor yourself?
Electrical power can be easily read on an adjustable controller, but mechanical power requires measuring torque and speed, which necessitates a dynamometer. Without a dynamometer, you can only compare power consumption per kilometer under identical conditions.