Torque and power of an electric motor: a simple explanation of the curve

An electric motor delivers strong power from a standstill, but its acceleration eventually decreases as it gains speed. This type of performance curve, which is very different from that of a combustion engine, is due to two simple limitations: the current that the motor and controller can handle, and the battery voltage. This guide explains what torque and power are, how they are related, and how to interpret the advertised figures without being misled.

The essentials

  • Torque is the rotational force; in an electric motor, it is proportional to the current.
  • Power is the product of torque and rotational speed: the same torque value results in more watts at higher speeds.
  • The curve has two distinct zones: it exhibits constant torque as long as the current is the limiting factor, and then transitions to constant power when the voltage becomes the limiting factor.
  • The rated power is the power that the motor can sustain without overheating, not the maximum power it can deliver for a few seconds.

Torque and power: two distinct quantities

The torque is the rotational force, measured in Newton-meters (N·m). This is what causes the vehicle to accelerate and climb hills. In a hub motor, which directly drives the wheel, the motor's torque divided by the wheel's radius gives the force that propels the scooter.

The power is the amount of work done per second, measured in watts (W). It combines force and speed:

Power (W) = Torque (N·m) × Speed (revolutions per minute) × 2π ÷ 60

Here's an example calculation: a motor that delivers 50 Nm of torque at 1,000 revolutions per minute develops 50 × 1,000 × 6.28 ÷ 60, which is approximately 5,240 Watts. The same motor, if it only delivers 25 Nm of torque but rotates at 2,000 revolutions per minute, develops the same power. Therefore, torque and power don't tell the same story: torque indicates how the machine starts, while power indicates what it can achieve at high speed.

The torque follows the current

In a motor with permanent magnets, the torque produced is proportional to the current flowing through the windings. The coefficient that relates them is called Kt, expressed in newton-meters per ampere; it depends on the magnets and the number of windings. Our guide Kv, Kt, and number of poles provides more details.

Direct consequence: the maximum torque is determined by the maximum current. This current is limited by the controller (what its transistors can handle), by the motor (what its windings and magnets can withstand without overheating), and, indirectly, by the battery. It is not the speed that limits the torque at startup; that's why an electric motor can deliver its full torque from a standstill.

The two-zone curve

Zone 1: Constant torque

At startup and at low speeds, the controller can send the maximum set current to the motor. This results in maximum, constant torque. The power, on the other hand, starts from zero when the vehicle is stopped and increases linearly with speed, as it is the product of torque and speed.

The starting point

When turning, the motor generates a voltage that opposes the battery's voltage, known as back electromotive force. This force increases with speed. Eventually, the controller reaches a point where it no longer has enough voltage headroom to push the maximum current into the motor windings: this is the base speed. Beyond this point, the current, and therefore the torque, begins to decrease.

Zone 2: Power remains relatively constant, then decreases

Above the base speed, the torque decreases as the speed increases. Ideally, the power remains relatively constant over a range of speeds. Then, as the speed approaches the no-load speed, the torque tends towards zero, and so does the power: the motor can no longer accelerate the vehicle.

Field weakening allows you to extend this second zone: the controller intentionally weakens the magnetic field to push the voltage limit, at the cost of increased current and heat. Our guide on field weakening explains how.

ZoneWhat limits..TorquePowerWhat you feel
Low speedMaximum current of the controller and the motorMaximum and constantIncrease the speedSmooth start, quick acceleration
High speedBattery voltageDecreaseApproximately constantThe acceleration becomes smoother
Close to no-load speedBattery voltageTend towards zeroFallThe machine is reaching its maximum limit

What shifts the curve

  • Increased Current (more capable controller and battery): The constant torque zone is extended. This results in stronger acceleration and faster recovery, without affecting the top speed.
  • Higher Voltage (higher voltage battery): The base speed and maximum speed are increased. The motor maintains its torque for longer and achieves higher speeds. See our guide on upgrading to a higher voltage.
  • Another winding option: A "High Speed" winding shifts the performance towards higher speeds, but requires more current to achieve the same torque; a "High Torque" winding does the opposite.
  • Battery voltage drop: Under heavy current, a worn-out or cold battery will experience a voltage drop, which reduces both the base speed and the top speed under load.

Nominal power and peak power

A motor advertised with a certain nominal power is not limited to that power. The nominal power is the power it can sustain over time without exceeding its temperature limit. The peak power is the power it can deliver for a few seconds, as long as its windings and magnets have not had time to heat up.

For example, our XHS75 High Speed motor is rated at 6,000W. This figure indicates the power it can continuously handle; the actual power delivered during acceleration depends on the controller, the battery, and the settings, and can exceed this value for short periods. Conversely, with a controller that has a limited power output, the motor will never reach its 6,000W rating.

The only reliable way to know the actual performance curves of a motor, controller, and battery combination is to measure them. Our guide on measuring power on a dynamometer explains how. For a machine being motorized from scratch, our engineering department starts with the required torque and speed to size the entire system for the machine.

Workshop tip

To compare two machines, focus on the torque at the wheel and the battery voltage rather than the advertised power in watts. A scooter that is advertised as very powerful but has a limited current output will feel sluggish when accelerating; a scooter that delivers a lot of current will feel responsive, even with a modest advertised power output.

Frequently Asked Questions

Why does an electric motor deliver its full torque from a standstill?

Because its torque depends on the current, not the speed. When stationary, the motor produces no voltage that opposes the battery: the controller can send the entire allowed current to it from the very first rotation of the wheel.

Why does my electric scooter accelerate less powerfully at high speeds?

Beyond the base speed, the battery voltage is no longer sufficient to deliver the maximum current to the motor. Torque decreases, and so does acceleration. This is normal and inherent to all electric motors powered by a battery.

Does adding the power of two motors make sense?

Yes, for a dual-motor scooter, the power outputs add up if both motors receive their current simultaneously. However, the battery must be able to supply power to both motors at the same time, which is often the real limiting factor.

Is the stated torque measured at the motor or at the wheel?

For a hub motor, the principle is the same, as the motor is located within the wheel. In a mid-drive motor with a chain or belt, the torque at the wheel is multiplied by the gear ratio, while the speed is reduced accordingly; the power remains the same, aside from transmission losses.