Electric motor winding: number of turns, voltage, and speed explained

Winding is the copper wire wrapped around the stator teeth. With identical size and magnets, it determines whether a motor spins fast or pushes hard, and how much current it demands from the controller and battery. The principle can be summarized in one sentence: the more turns, the more torque the motor produces per ampere and the slower it spins per volt.

The essentials

  • The number of turns determines the voltage the motor produces while spinning, and thus its maximum speed for a given battery.
  • Fewer turns: more speed, but more current for the same torque. More turns: the opposite.
  • In the same stator, the space for copper is fixed: fewer turns means thicker wire, or more strands in parallel.
  • Star or delta coupling also changes the motor speed, without touching the wire.
  • Rewinding a scooter motor is a specialist's job: an insulation fault results in a short circuit.

What a turn is, and what it produces

A turn is one loop of wire around a stator tooth. When the rotor spins, its magnets pass in front of the teeth, and the magnetic field passing through each turn varies. This variation creates a voltage in the wire: this is the back electromotive force. Each turn adds its small part, and the total voltage of a phase is the sum of all its turns.

This voltage increases with speed. The motor reaches its maximum speed when the voltage it produces equals the voltage the controller can apply to it, i.e., at best, the battery voltage. Hence the rule: more turns, more voltage produced per revolution, therefore a lower ceiling speed. This is exactly what Kv describes, detailed in our guide Kv, Kt and number of motor poles.

Conversely, the same phenomenon produces torque: a current flowing through many turns creates a stronger field than a current flowing through few. More turns, therefore more torque for every ampere.

The same stator, two windings: real figures

Our product pages show the effect of winding on motors of the same size. The FHS60 and FHT60 motors both have 60 mm magnets. The speed version, FHS60, spins at no load at 2,900 RPM at 60 V; the torque version, FHT60, at 1,380 RPM at the same voltage. More than twice as slow, with the same iron and magnets: only the number of turns changes.

Another example: the XHS75 motor spins at no load at 2,340 RPM at 60 V and at 2,808 RPM at 72 V. The speed ratio is the same as the voltage ratio (72 ÷ 60 = 1.2). For a given winding, the no-load speed follows the battery voltage, which confirms that it is indeed the back EMF that sets the ceiling.

These two winding families are what we call High Speed and High Torque. The choice between the two, depending on usage and battery, is covered in our guide High Speed or High Torque.

Copper space: cross-section, strands, and fill factor

The stator slots, the gaps between the teeth, have a fixed volume. The winder must fit the copper in there, along with its insulating varnish, slot liners, and a bit of clearance for the wire. The portion of this volume actually occupied by copper is called the fill factor. The higher it is, the lower the motor's resistance, and the less it heats up at the same current.

This space constraint links the number of turns to the wire cross-section:

  • Few turns: there is room left for thicker wire. Resistance drops, which is convenient, as this winding will demand more current.
  • Many turns: requires thinner, longer, and therefore more resistant wire. But it demands less current for the same torque.

A very thick wire is difficult to bend around a tooth and fills the corners of the slot poorly. It is therefore often replaced by several thin wires wound together, in parallel: these are the strands. They behave like a single thick wire but pack better.

A surprising consequence

If you divide the number of turns by two while keeping the same fill factor, each turn has twice the cross-section, and the wire is twice as short. The resistance is divided by four. The motor demands twice as much current for the same torque, but the losses in the copper, which follow the current squared multiplied by the resistance, remain the same. For the same size and well-executed winding, a High Speed and a High Torque motor therefore heat up just as much for the same torque: the difference lies in what the controller, cables, and battery must handle.

Star or delta: the coupling of the three phases

A three-phase motor has three windings, one per phase. They can be connected in two ways:

StarDelta
ConnectionOne end of each phase connected to a common point, the neutralThe three phases connected end-to-end, in a loop
Speed per voltLowerHigher, by a factor of the square root of 3 (about 1.73)
Current for the same torqueLowerHigher
SpecificsMost common on scooter motorsCurrents can circulate in a loop within the delta and add losses

Coupling is therefore a second lever, alongside the number of turns. It is decided at the design stage: on a hub motor, the connection point is enclosed inside the motor, and changing it means opening and reworking the winding.

Winding and battery voltage: choosing the right pair

A winding is never good or bad in absolute terms: it must match the battery voltage and the current the controller can provide.

  • A low-turn winding on a high-voltage battery can make the motor spin faster than the wheel, bearings, or rider can handle, or faster than the controller can keep up with.
  • A high-turn winding on a low-voltage battery will result in a torquey but slow machine.
  • A low-turn winding with a current-limited controller will result in a sluggish machine at startup: torque is lacking due to a lack of amps.

This is why we always reason in terms of the motor, controller, and battery as a whole. When a machine is out of the ordinary, our engineering department sizes the winding for the machine and its usage, rather than starting from an off-the-shelf motor.

Rewinding it yourself: why it's a false good idea

Changing the number of turns of an existing motor seems simple on paper. In practice, it is a long and risky job:

  • the wire varnish is easily damaged when passing through the slots; a single scratch can put two turns in contact, and the motor will heat up and then burn out at that spot;
  • you must strictly follow the winding diagram, the direction of each tooth, and the distribution between phases, otherwise the motor will vibrate, stutter, or not turn;
  • you must achieve the correct fill factor, otherwise the rewound motor will heat up more than the original;
  • you must open the motor and separate the rotor, with its very powerful magnets, from the stator: an operation dangerous for your fingers;
  • finally, you must impregnate the winding against vibrations and redo the phase outputs.

To change the character of a machine, it is safer to choose a motor already wound for the intended use. Most of our electric scooter motors are available in both speed and torque versions.

Workshop advice

Before choosing a winding, note your full battery voltage and the phase current your controllers can provide. When in doubt, the higher-torque winding is more forgiving.

Frequently asked questions

Is a motor with fewer turns more powerful?

Not necessarily. It spins faster for the same voltage, but it needs more current to produce the same torque. For the same size, the power a motor can handle depends primarily on its ability to dissipate heat, not on the number of turns.

Can you tell how many turns a motor has without opening it?

Not directly, but the no-load speed for a given voltage and the resistance between phases give a good idea of its winding. Two motors of the same size where one spins much faster than the other at the same voltage have different windings.

Why does my motor have several thin wires per phase rather than one thick one?

These are strands in parallel. They pack better in the slots than a large, rigid wire, improve the fill factor, and limit certain high-frequency losses. Electrically, they act as a single large-section conductor.

Does switching from star to delta make the scooter faster?

In theory, yes: the speed per volt increases by about 1.73 times. But the current demand increases by the same amount for the same torque, and internal currents can add losses. On a hub motor, the modification requires opening the motor: this is not an improvement to attempt yourself.